sql

Kabel Voksel NA2XSY

Rp. CALL
Update Terakhir
11 Des 2023
Pembelian Min
1 mtr
Kategori
Kabel Voksel

Kabel VokselN2XSY NA2XSY



Info Harga dan Diskon / komisi, WA : Simpati12 812 1843 3055



Ukuran :







































NA2XSY. 1 x 50 mm2 - 12/20 Kv
NA2XSY. 1 x 70 mm2 - 12/20 Kv
NA2XSY. 1 x 95 mm2 - 12/20 Kv
NA2XSY. 1 x 120 mm2 - 12/20 Kv
NA2XSY. 1 x 150 mm2 - 12/20 Kv
NA2XSY. 1 x 185 mm2 - 12/20 Kv
NA2XSY. 1 x 240 mm2 - 12/20 Kv
NA2XSY. 1 x 300 mm2 - 12/20 (24) Kv
NA2XSY. 1 x 400 mm2 - 12/20 (24) Kv
NA2XSY. 1 x 500 mm2 - 12/20 (24) Kv
NA2XSY 1 x 630 mm2 -12/20 (24) Kv



1 CORE CABLE TYPE N2XSY, NA2XSY


SINGLE CORE CABLE




  • COPPER OR ALUMINIUM CONDUCTOR,

  • XLPE INSULATED,

  • COPPER WIRES SCREENED AND PVC SHEATHED

  • Type N2XSY, NA2XSY


Feature XLPE insulated single core cables are applied for installation indoors, outdoors, underground and cable rack.



CONSTRUCTION



Conductor Stranded compacted circular copper or aluminium conductors. All internal interstices of trie conductor rilled with water blocking compound which is specified to prevent ingress of water through conductor during storage, handling, installation and operating of the cable.



Conductor Screen Extruded Semi-conducting compound. Minimum thickness 0.5 mm and the maximum volume resistivity of 5000 ohm-an at 20° C and 25000 ohm-cm at 90° C.



Insulation Extruded XLPE with high degree of cross-linking, free from contaminants, air voids and heat resistant by dry cured process.



The nominal thickness as shown in table 1.





















Type : N2XSY

NA2XSY
Nominal Voltage : 3.6/6 ( 7.2 ) kV

6/10 ( 12 ) kV

8.7/15 ( 17.5 ) kV

12/20 ( 24 ) kV

18/30 ( 36 ) kV
Specification : SPLN 43-5

(Other Specifications are availible upon request)

Table 1. Insulation Thickness



Tabel 2 . Minimum Total Cross Section Of Metallic Screen



Insulation Screen Extruded Semi-conducting compound. Minimum thickness 0.5 mm and the maximum volume resistivity of 5000 ohm-cm at 20°C and 25000 ohm-cm at WC The screen is tightly fitted to insulation to exdude all air voids and can be easily hand stripped on site.



Conduction Water Blocking Layer Semi-conductive water blocking tape provided over the insulation screen which will swell up under the influence ofmoisture or water.



Metallic Screen Copper wires applied over the conducting water blocking layer. Minimum cross section of concentric conductor as shown in table 2. Copper tape with minimum thickness 0.1 mm and maximum 0.3mm applied over copper wires.



Water Blocking Layer Non-conducting water blocking tape provided the metallic screen which will swellup under ihe influence of moisture or water.



Outer Sheath Extruded red PVC, suitable tar exposure to sun-light or other local atmospheric environments and for the operating temperature of the cable.