sql

Kabel Voksel NFA2XSY

Rp. CALL
Update Terakhir
30 Mar 2023
Pembelian Min
1000 mtr
Kategori
Kabel Voksel

Cable VokselNFA2XSY


Info Harga dan Diskon / komisi, WA : Simpati12 812 1843 3055


Ukuran :

















NFA2XSY.T 3x70 + 1x50 mm2 -12/20 (24) Kv - CWS
NFA2XSY. T 3 x 95 + 50 mm2 - 12/20 (24) Kv
NFA2XSY. T 3 x 150 + 95 mm2 - 12/20 (24) Kv - CWS
NFA2XSY. 3 x 240 + 95 mm2 - 12/20 Kv - CWS


VE - OVERHEAD TWISTED CABLE TYPE NFA2XSY-T


OVERHEAD TWISTED CABLE



  • ALUMINIUM CONDUCTOR,

  • XLPE INSULATED,

  • COPPER WIRES SCREENED AND PVC SHEATHED

  • Type NFA2XSY-T


Feature

XLPE insulated twisted cables are applied for specially overhead installation.


CONSTRUCTION


Conductor

Stranded compacted circularaluminium conductors. All internal interstices of trie conductor rilled with water blocking compound which is specified to prevent ingress of water through conductor during storage, handling, installation and operating of the cable.


Conductor Screen

Extruded Semi-conducting compound. Minimum thickness 0.5 mm and the maximum volume resistivity of 5000 ohm-cn at 20° C and 25000 ohm-cm at 90° C.


Insulation

Extruded XLPE with high degree of cross-linking, free from contaminants, air voids and heat resistant by dry cured process.


The nominal thickness as shown in table 1.




















Type NFA2XSY-T
Nominal Voltage 3.6/6 ( 7.2 ) kV

6/10 ( 12 ) kV

8.7/15 ( 17.5 ) kV

12/20 ( 24 ) kV

18/30 ( 36 ) kV
Specification SPLN 43-5

(Other Specifications are availible upon request)

Table 1. Insulation Thickness


Tabel 2 . Minimum Total Cross Section Of Metallic Scree


Insulation Screen

Extruded Semi-conducting compound. Minimum thickness 0.5 mm and the maximum volume resistivity of 5000 ohm-cm at 20°C and 25000 ohm-cm at WC The screen is tightly fitted to insulation to exdude all air voids and can be easily hand stripped on site.


Conduction Water Blocking Layer

Semi-conductive water blocking tape provided over the insulation screen which will swell up under the influence ofmoisture or water.


Metallic Screen

Copper wires applied over the conducting water blocking layer. Minimum cross section of concentric conductor as shown in table 2. Copper tape with minimum thickness 0.1 mm and maximum 0.3mm applied over copper wires.


Water Blocking Layer

Non-conducting water blocking tape provided the metallic screen which will swellup under ihe influence of moisture or water.


Outer Sheath

Extrudedblack PVC, suitable tar exposure to sun-light or other local atmospheric environments and for the operating temperature of the cable.


Messenger

Stranded galvanized steel wire with 19 wires and cross section 50 mm2, Insulated by extruded PVC which capable for operating continuously at maximum temperature of the cable. Nominal insulation thickness is 1.2 mm.



Lihat Selengkapnya

Untuk keterangan lebih lanjut, silahkan download PDF ini :

Ulasan

/5
Ulasan
5
4
3
2
1

Foto dari Pembeli

Ulasan dari Pembeli

Filter
Semua
Dengan Foto
5
4
3
2
1
Minta Penawaran
Produk Siap di Pesan
Rp 0
1